Categories
- Pipe & Tube (18)
- Flange & Fitting (97)
- Fastener & Gasket (12)
- Valve & Pump (18)
- Base Material (10)
- Equipment (8)
- Application (28)
- Technical (109)
EN 1092-1 flanges, either made from EN 10273 P250GH hot rolled bars or EN 10222-2 P250GH forgings, are classified into material group 3E0. The pressure-temperature ratings (p/T ratings) for P250GH indicate the maximum allowable pressure (M.A.S in bar unit) at maximum allowable temperature (Temp. in °C unit) for various PN designations of P250GH flanges. The p/T ratings are dependent on the actual flange thickness (vR in mm unit).
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 2.5 | 2.5 |
100 | 2.3 | 2.1 |
150 | 2.2 | 2.0 |
200 | 2.0 | 1.9 |
250 | 1.9 | 1.7 |
300 | 1.7 | 1.6 |
350 | 1.6 | 1.5 |
400 | 1.4 | 1.4 |
450 | 0.8 | 0.8 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 6.0 | 6.0 |
100 | 5.5 | 5.1 |
150 | 5.2 | 5.0 |
200 | 5.0 | 4.6 |
250 | 4.5 | 4.2 |
300 | 4.1 | 3.8 |
350 | 3.8 | 3.6 |
400 | 3.5 | 3.4 |
450 | 1.9 | 1.9 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 10.0 | 10.0 |
100 | 9.2 | 8.5 |
150 | 8.8 | 8.3 |
200 | 8.3 | 7.7 |
250 | 7.6 | 7.0 |
300 | 6.9 | 6.4 |
350 | 6.4 | 6.0 |
400 | 5.9 | 5.7 |
450 | 3.2 | 3.2 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 16.0 | 16.0 |
100 | 14.8 | 13.7 |
150 | 14.0 | 13.3 |
200 | 13.3 | 12.4 |
250 | 12.1 | 11.3 |
300 | 11.0 | 10.2 |
350 | 10.2 | 9.6 |
400 | 9.5 | 9.1 |
450 | 5.2 | 5.2 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 25.0 | 25.0 |
100 | 23.2 | 21.4 |
150 | 22.0 | 20.8 |
200 | 20.8 | 19.4 |
250 | 19.0 | 17.7 |
300 | 17.2 | 16.0 |
350 | 16.0 | 15.1 |
400 | 14.8 | 14.2 |
450 | 8.2 | 8.2 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 40.0 | 40.0 |
100 | 37.1 | 34.2 |
150 | 35.2 | 33.3 |
200 | 33.3 | 31.0 |
250 | 30.4 | 28.3 |
300 | 27.6 | 25.7 |
350 | 25.7 | 24.1 |
400 | 23.8 | 22.8 |
450 | 13.1 | 13.1 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 63.0 | 63.0 |
100 | 58.5 | 54.0 |
150 | 55.5 | 52.5 |
200 | 52.5 | 48.9 |
250 | 48.0 | 44.7 |
300 | 43.5 | 40.5 |
350 | 40.5 | 38.1 |
400 | 37.5 | 36.0 |
450 | 20.7 | 20.7 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 100.0 | 100.0 |
100 | 92.8 | 85.7 |
150 | 88.0 | 83.3 |
200 | 83.3 | 77.6 |
250 | 76.1 | 70.9 |
300 | 69.0 | 64.2 |
350 | 64.2 | 60.4 |
400 | 59.5 | 57.1 |
450 | 32.8 | 32.8 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 160.0 | 160.0 |
100 | 148.5 | 137.1 |
150 | 140.9 | 133.3 |
200 | 133.3 | 124.1 |
250 | 121.9 | 113.5 |
300 | 110.4 | 102.8 |
350 | 102.8 | 96.7 |
400 | 95.2 | 91.4 |
450 | 52.5 | 52.5 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 250.0 | 250.0 |
100 | 232.1 | 214.2 |
150 | 220.2 | 208.3 |
200 | 208.3 | 194.0 |
250 | 190.4 | 177.3 |
300 | 172.6 | 160.7 |
350 | 160.7 | 151.1 |
400 | 148.8 | 142.8 |
450 | 82.1 | 82.1 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 320.0 | 320.0 |
100 | 297.1 | 274.2 |
150 | 281.9 | 266.6 |
200 | 266.6 | 248.3 |
250 | 243.8 | 227.0 |
300 | 220.9 | 205.7 |
350 | 205.7 | 193.5 |
400 | 190.4 | 182.8 |
450 | 105.1 | 105.1 |
Temp. °C | M.A.S for vR≤50 bar | M.A.S, for 50<vR≤150 bar |
---|---|---|
RT | 400.0 | 400.0 |
100 | 371.4 | 342.8 |
150 | 352.3 | 333.3 |
200 | 333.3 | 310.4 |
250 | 304.7 | 283.8 |
300 | 276.1 | 257.1 |
350 | 257.1 | 241.9 |
400 | 238.0 | 228.5 |
450 | 131.4 | 131.4 |